1. Establish the defendable space
Defendable space is the zone around a building that is managed to reduce the fuel load available for a bushfire. The Planning and Design Code and CFS guidance specify defendable space dimensions and vegetation requirements.
The immediate zone (typically the first 10 to 20 metres from the building) should have minimal fuel: no shrubs, mown grass, and any trees pruned so canopies do not touch the building. Non-combustible mulch or hard landscaping is preferred over bark mulch.
The outer zone (typically 20 to 100 metres from the building depending on BAL level) can have more vegetation but should be managed to reduce fire intensity: canopy separation to prevent crown fire, no ladder fuels (shrubs that carry fire from ground to canopy), and cleared understorey.
Vegetation management in the defendable space is an ongoing responsibility. Annual pruning, grass mowing and leaf litter removal are all required to maintain the defendable space effectiveness.