1. The six BAL levels and what each means
The BAL scale under AS 3959-2018 defines six levels of bushfire attack severity.
BAL-Low: insufficient risk to require specific bushfire construction measures. No AS 3959 provisions apply.
BAL-12.5: ember attack is the primary threat. Construction requirements focus on window screens, ember-proof roof detailing, and non-combustible materials in specific vulnerable areas.
BAL-19: ember attack plus low radiant heat (up to 19 kW/m²). Requirements expand to include some wall and roof cladding restrictions.
BAL-29: ember attack plus significant radiant heat (up to 29 kW/m²). Bushfire-resistant materials required for walls, roof, windows and doors.
BAL-40: severe radiant heat (up to 40 kW/m²) plus embers. Very restrictive material requirements; construction cost increases materially.
BAL-FZ (Flame Zone): direct flame contact possible. Highest level of protection required, with steel-framed construction, radiant heat barriers, and severely restricted material choices.