1. Fire separation requirements
The NCC 2025 requires a fire-resistance level between the two dwellings in a duplex. The specific requirement depends on the building classification and the storey count.
For most residential duplexes, a Fire Resistance Level of at least 60/60/60 (60 minutes structural adequacy, 60 minutes integrity, 60 minutes insulation) is typical. Higher requirements apply for larger multi-storey duplexes.
The party wall must extend from the foundation to the roof and must be continuous through any ceiling space. Standard construction: two independent stud walls each with plasterboard, mineral wool insulation in the cavities, and a rated fire-stopping detail at the ceiling and floor junctions.
Fire penetrations (services crossing the wall) are typically prohibited. All services should be routed within each dwelling and not cross the party wall. Where a penetration is unavoidable, it must be fire-stopped to the same rating as the wall.