1. The six BAL levels and what each means
The BAL scale under AS 3959-2018 defines six levels of bushfire attack severity.
BAL-LOW: insufficient risk to require specific bushfire construction measures.
BAL-12.5: ember attack is the primary threat. Window screens, ember-proof roof detailing and non-combustible materials in vulnerable areas.
BAL-19: ember attack plus radiant heat up to 19 kW/m2. Some wall and roof cladding restrictions.
BAL-29: ember attack plus radiant heat up to 29 kW/m2. Bushfire-resistant materials for walls, roof, windows and doors.
BAL-40: severe radiant heat up to 40 kW/m2 plus embers. Very restrictive material requirements and a material cost increase.
BAL-FZ (Flame Zone): direct flame contact possible. Highest protection, typically steel-framed construction and radiant-heat barriers.