Soil Classification

Soil Classification (M, H1, H2, P): What It Means for Your Footings

Quick answer

A soil classification for a new Adelaide home is issued under Australian Standard AS 2870. Classes range from A (stable) through S, M, H1, H2, E to P (problem site). Most Adelaide blocks return M or H1. The class is set by a soil test, and it is what your engineer uses to design the foundation. A more reactive class generally means a stronger foundation and a higher cost.

Adelaide sits on some of the most reactive clay soils in Australia. A soil test on your block returns a classification under AS 2870, and that letter is what your engineer uses to design the foundation, which in turn flows through to your build cost. Understanding the class up front removes surprises later.

Public source: Australian Standard AS 2870 Residential slabs and footings

Section 1

Class A: stable

Sand and rock sites with little to no movement. Rare in metropolitan Adelaide. Standard footings, no special engineering.

Section 2

Class S: slightly reactive

Slight surface movement possible. Uncommon in Adelaide but appears in some coastal sand-belt suburbs. Standard footings with minor allowances.

Section 3

Class M: moderately reactive

Moderate clay movement. Very common across Adelaide plains. A standard engineered slab is usually designed for this, and most volume builders use M class as their baseline.

Section 4

Class H1: highly reactive

Significant clay movement. Common across the western suburbs, the plains, and some Hills areas. This usually means a stronger, more engineered foundation than M class, which your engineer designs for the block.

Section 5

Class H2: very highly reactive

Very high clay movement. Common on the deeper black clay plains north and west of Adelaide. This typically calls for a more heavily engineered foundation again, and it is where foundation costs start to climb sharply.

Section 6

Class E: extremely reactive

Extreme movement. Rare but possible on specific parcels. These blocks need a bespoke foundation designed by a structural and geotechnical engineer.

Section 7

Class P: problem sites

Fill, softness, uncontrolled soil movement, mine subsidence, or a combination. These sites need site-specific engineering designed by a qualified engineer, and cannot be worked out from a standard footing table.

Adelaide soil classifications under AS 2870
ClassReactivityAdelaide prevalenceWhat it usually means
AStableRare (sand/rock)A standard foundation
SSlightly reactiveCoastal sand beltA standard foundation, minor allowances
MModerately reactiveVery common (plains)A standard engineered slab
H1Highly reactiveCommon (western/plains)A stronger, more engineered foundation
H2Very highly reactiveDeep black clay (N/W)A more heavily engineered foundation; cost climbs
EExtremely reactiveRare specific parcelsA bespoke foundation your engineer designs
PProblem siteFill / mine / mixedSite-specific engineering by a qualified engineer

Section 8

How to find out early

Any builder or designer can commission a soil test on the block before you commit to a design. It is inexpensive relative to redoing engineering later. If you are buying land, ask the vendor whether a test has already been done. If yes, ask for it. If no, factor a test into your due diligence.

This is general planning and technical information drawn from public sources. It is not legal, planning, or engineering advice. Rules and overlays change; always confirm current requirements directly through SAPPA and engage a qualified professional (town planner, building designer, private certifier, arborist, or geotechnical engineer) for your specific block.

Cookies on. Learn more